Spinner Turbines for Bruker® Spectrometers
Bruker® Room Temperature 5 & 10mm Spinner Turbine
Highlights
• Less probe insert damage due to better
insert sample control
• Longer upper barrel stabilizer with 3mm
yellow band
• Can be mixed with originals during sample
changer operation
Bruker® Room Temperature 5 & 10mm Spinner Turbines
STB-5 | Ambient | 5mm Spinner for Bruker® |
---|---|---|
STB-5-TACHO | — | Replacement Tacho-Strip |
TURBINE-ORING-BLACK | — | Replacement 5mm Viton® O-Ring |
STB-10 | Ambient | 10mm Spinner for Bruker® |
Bruker® Variable Temperature 5 & 10mm Spinner Turbines
Highlights in addition to previous
• Far less likely to break than ceramic
spinners if dropped on a hard surface
• Weight is comparable to room
temperature spinners
• Long life high-temperature top and
bottom O-rings
Bruker® Variable Temperature 5 & 10mm Spinner Turbines
Catalog No. | Application Temperature | Description |
---|---|---|
B-PEEK-5 | -150 to 200° C | 5mm PEEK Spinner for Bruker® |
B-PEEK-10 | -150 to 200° C | 10mm PEEK Spinner for Bruker® |
B-PEEK-5-O-RING | — | Replacement 5mm Viton® O-Ring |
B-PEEK-10-O | — | Replacement 10mm O-Ring |
Bruker® 3 to 5mm Spinner Turbine with Exchangeable Fingers
Highlights in addition to previous
• Allows a portion of the VT air to pass straight through the sample inside the spinner t urbine therefore reducing VT gradients and micro sonic flutter due to any high VT flow
• Includes high temperature external O-rings at the top and bottom for long life and a firm grip on the sample
• Optimized for non-spinning experiments but compatible with spinning experiments
• No need to adjust eject air to eject sample
• The mass multiplier ring is not included but can be purchased separately
Bruker® Variable Temperature 3 to 5mm Spinner Turbines with Exchangeable Fingers
Catalog No. | Application Temperature | Description | Material |
---|---|---|---|
B-PEEK-3-NS | -150 to 200° C | Bruker® Spinner Turbine with 3mm PEEK exchangeable fingers | PEEK |
B-PEEK-4-NS | -150 to 200° C | Bruker® Spinner Turbine with 4mm PEEK exchangeable fingers | PEEK |
B-PEEK-5-NS | -150 to 200° C | Bruker® Spinner Turbine, with 5mm PEEK exchangeable fingers | PEEK |
UNI-FINGER-PEEK-3 | -150 to 200° C | 3mm Finger for B-PEEK-X-NS Turbines (Two Required), Double VT O-Ring | PEEK |
UNI-FINGER-PEEK-4 | -150 to 200° C | 4mm Finger for B-PEEK-X-NS Turbines (Two Required), PEEK, Double VT O-Ring | PEEK |
UNI-FINGER-PEEK-5 | -150 to 200° C | 5mm Finger for B-PEEK-X-NS Turbines (Two Required), PEEK, Double VT O-Ring | PEEK |
UNI-MASS-MULTI | — | Mass Multiplier Ring for Bruker® Style Spinner Turbines with 1 or 2 O-Rings at the top | — |
Spinner Turbines for Agilent® (Varian®) Spectrometers
Agilent® Room Temperature 5mm & 10mm Spinner Turbine
Highlights
• Can be mixed with originals in sample changer operation
• Does not jam at top of upper barrel
during insert operation
Agilent® Room Temperature 5 & 10mm Spinner Turbines
Catalog No. | Application Temperature | Description |
---|---|---|
STV-5 | Ambient | 5mm Spinner for Agilent® |
STV-5-TACHO | — | Replacement Tacho-Strip |
TURBINE-ORING-RED | — | Replacement 5mm O-Ring |
Agilent® Variable Temperature 5mm & 10mm Spinner Turbine
Highlights in addition to previous
• Weight compatible with room temperature spinners
• Cost effective as compared to the originals
• Long life high-temperature top and bottom O-rings
Bruker® Variable Temperature 5 & 10mm Spinner Turbines
Catalog No. | Application Temperature | Description |
---|---|---|
B-PEEK-5 | -150 to 200° C | 5mm PEEK Spinner for Bruker® |
B-PEEK-10 | -150 to 200° C | 10mm PEEK Spinner for Bruker® |
B-PEEK-5-O-RING | — | Replacement 5mm Viton® O-Ring |
B-PEEK-10-O | — | Replacement 10mm O-Ring |
Agilent® 3 to 5mm Spinner Turbine with Exchangeable Fingers
Highlig
Highlights in addition to previous
• Allows a portion of the VT air to pass straight through the sample inside the spinner turbine therefore reducing VT gradients and micro sonic flutter due to any high VT flow
• Includes high temperature external O-rings at the top and bottom for long life and a firm grip on the sample
• Optimized for non-spinning experiments but compatible with spinning experiments
• No need to adjust eject air to eject sample
• The mass multiplier ring is not included but can be purchased separately
Agilent® 3 to 5mm Variable Temperature Spinner Turbines with Exchangeable Fingers
Catalog No. | Application Temperature | Description | Material |
---|---|---|---|
V-PEEK-3-NS | -150 to 200° C | Agilent^{®} Spinner Turbine with 3mm PEEK exchangeable fingers | PEEK |
V-PEEK-4-NS | -150 to 200° C | Agilent^{®} Spinner Turbine with 4mm PEEK exchangeable fingers | PEEK |
V-PEEK-5-NS | -150 to 200° C | Agilent^{®} Spinner Turbine with 5mm PEEK exchangeable fingers | PEEK |
UNI-FINGER -PEEK-3 | -150 to 200° C | 3mm Finger for V-PEEK-X-NS style turbines (Two Required), Double VT O-Ring | PEEK |
UNI-FINGER -PEEK-4 | -150 to 200° C | 4mm Finger for V-PEEK-X-NS style turbines (Two Each Re-quired), PEEK, Double VT O-Ring | PEEK |
UNI-FINGER -PEEK-5 | -150 to 200° C | 5mm Finger for V-PEEK-X-NS style turbines (Two Each Re-quired), PEEK, Double VT O-Ring | PEEK |
UNI-MASS-MULTI | — | Mass Multiplier Ring for V-NS Style Spinner Turbines with 1 or 2 O-Rings at the top |